Resources / Gland Calculator
O-ring gland calculator
Check squeeze, gland fill, stretch and the need for back-up rings, in inches and psi.
Typical design ranges
| Check | Static | Dynamic | Why it matters |
|---|---|---|---|
| Squeeze | 15 to 30% | 10 to 20% | Too little leaks at low pressure; too much takes a compression set and raises friction |
| Gland fill | 75% or less | 75% or less | Leaves room for swell and thermal expansion |
| Stretch (piston glands) | 0 to 3% | 0 to 3% | Stretch thins the cross-section and shortens life |
| Extrusion gap | Depends on pressure and hardness | Depends on pressure and hardness | Too large a gap nibbles the O-ring; back-up rings close it |
These are general screening ranges used across the industry. Your application may justify different values; we check every gland on the quote.
Send the gland with your RFQ.
Include the drawing or the dimensions above. We confirm squeeze, fill and extrusion before quoting.